S3800

S3800E Series Closed-loop vector control – High performance:  Control of asynchronous motor and synchronous motor are implemented through the high-performance current vector control technology.
Overload capacity 60s for 150% of the rated current, 3s for 180%( 120%) of the rated current.
Ramp mode: Straight-line ramp; S-curve ramp; Four groups of acceleration/deceleration time with the range of 0.0–6500.0s

Category:
Item S3800E
V/F control
Control mode Sensorless flux vector control (VC)
Cloed-loop vector control(CVC)
Vextor control :0~320Hz
Maximum frequency V/F control :0~3200Hz
Dgital setting :0.01Hz
Input frequency esolution Analog setting :0.025% of maximum frequency
G type :0.5Hz/150%; 0 Hz/ 180%(CLVC)
Startup torque P type :0.5Hz/100%
1:100(SFVC)
Speed range 1:1000(CLVC)
Speed stability accuracy ±0.2%(CLVC)
±0.5%(SFVC)   ± 0.02%(CLVC)
Torque control accuracy ±5%(CLVC)
Overload capacity G type : 60s for 150% of the rated current, 3s for 180% of the rated current
P type : 60s for 120% of the rated current, 3s for 150% of the rated curren
Torque boost Auto boost
Customized boost 0.1%-30.0%
V/F curve Multi-point curve
N-power V/F curve (1.2 power ,1.4 power,1.6 power,1.8power,square )
V/F separation Two types :complete separation ; half separation
Ramp mode Straight-line ramp
S-curve ramp
Four groups of acceleration /deceleration time with the range of 0.0.-6500s
DC braking DC braking frequency :0.00HZ to maximun frequency
Braking time :0.0~100.0s
Braking action current value :0.0%- 100.0%
JOG control JOG frequency range :0.00~ 50.00HZ
JOG acceleration /deceleration time :0.0~ 6500.0s
Onboard multiple preset speeds It implements up to 16 speeds via the simple PLC function or combination of terminal states
Onboard PID It realizes process-controlled closed loop control system easily
Auto voltage Regulation (AVR) It can keep constant output voltage automatically when the mains voltage changes.
Overvoltage /Overcurrent stall control The current and voltage are limited automatically during the running process so as to avoid frequenct tripping due to overvoltage /over current
Torque limit and control It can limit torque automatically and prevent frequent over current tripping during the running process .Torque control can be implemented in the CVC mode
Support for the multiple PG card Support for rotating transformer PD card , differential input PG card, resolver PG card and OC input PG card
Power dip ride through Reduction so that the AC drive can continue to run for a short time
Rapid current limit It helps to avoid frequent over current faults of the AC drive
High performance Control of asynchronous motor and synchronous motor are implemented through the high -performance current vector control technology .
Timing control Time range : 0.0~ 6500.0  mintes
Communication Methods MODBUS -RTU \ PROFIBUS -DP\ CAN
Protection mode Motor short -circuit detection at power -on , input/output phase loss protection ,over current protection, overvoltage protection, under voltage protection , overheat protection and overload protection
Installtion Location Indoor , free from direct sunlight , dust , corrosive gas, combustible gas, oil smol, vapour , drip or salt
Altitude Lower than 1000m
Ambient temperature -10-40de-rated if the ambient temperature is between 40 and 50
Storage temperture -20~60