Product description: Power range : 0.4kW-5.5kW   220V
0.75kW-630kW   380V
Advantage: Copy parameter function
Pulse input/output
PNP & NPN Avaible

Category:
Item                        S1100V
Power range 1.5KW~630KW(normal duty)
0.75KW~550KW(heavy duty)
380V(3phase)50/60Hz
Voltage range (-15%…+20%)of rated voltage
Control mode V/F control
Vector flux control
Basic function Maximum frequency 600Hz
Input frequency resolution Digital setting: 0.01Hz
Analog setting: maximum frequency ×0.1%
Startup torque G modle: 0.5Hz/180%(heavy duty)
P model: 0.5Hz/120%(normal duty)
Speed adjustment range 1:200(Open loop Vector flux control)
Torque response ≤40ms(Open magnetic flux vector control)
Overload capacity G model: 150% rated current 60s; 180% rated current 3s
P model: 130% rated current 60s; 150% rated current 3s
Torque hoist Automatic torque hoist; manual torque hoist 0.1% to 30.00%
V/F curve Linear V/F, Multi-point V/F, and Square V/F
Speed-up and Speed-down curve Straight line or S curve speed-up and speed-down
mode;Two kinds of speed-up and speed-down time
Acceleration/Deceleration time Speed-up and speed-down time ranges between 0.0s to 3000s
DC brake DC brake frequency:0.00~400.00Hz
brake time:0.0s to 36.0s,and brake current value: 0.0% to 100.0%.
Jog control Jog frequency range:0.00Hz to 50.00Hz;
jog speed-up/speed-down time: 0.0s to 3000.0s.
Simple PLC and MS speed running It can realize a maximum of 16 segments speed running
via the built-in PLC or control terminal.
Built-in PID It is easy to realize process-controlled close loop control system
voltage regulation(AVR)Auto It can keep constant output voltage automatically in case
of change of mains voltage.
Torque limit
and control
“Shovel” characteristics, the runtime automatic torquelimit, prevent frequent
over-current trip; closed loop vectormodel can realize the torque control
Individua-lized function Peripherals self-detection upon power-on It can conduct safety detections on the peripherals upon power-on,
including earth and short circuit detections.
Shared DC bus function It can realize the function that multiple inverters share the DC bus.
JOG key Programmable key: Select the command channel switching/forward
and reverse rotations/jog operation.
Display and Keyboard LED display The machine has the LED keyboard,and realize parameter
settings,status monitoring function.
LCD display Optional, / English prompts content
Operation Parameter Copy Keyboard can be copied using the parameters to achive
the rapid replication parameter
   structure Protective IP20